|
HYFIRE 7C BTR CONTROLLER
HyFIRE 7C BTR Controller: 3 Stages of Rev Limiting in 50 RPM Steps. 3 stages of Ignition Retard- Each one Adjustable .1 to 25 degrees in tenth degree steps. Adjustable Automatic Start Retard. Selectable High Speed Advance Slope. Boost Proportional Retard Harness - Plugs into 2 or 3 BAR MAP Sensor (Sensor Sold Separately - Order Part No. 716 for 2 BAR or Part No. 717 for 3 BAR) Features At A Glance: No Chips required For Adjustments. Easy to use push button controls. Upgrade your Hyfire 7S to a 7C, 7CR, 7C BTR without changing your Entire Ignition. Upgrade your present Hyfire 7C to a 7CR, 7C BTR without changing your Entire Ignition. RPM Switch (When Upgrading a HyFIRE 7C Only). Simply plug in the new controller and wire up the new features.
Part Number:
676M
|
|
HYFIRE 7C CONTROLLER
HyFIRE 7C Controller: 3 Stages of Rev Limiting in 50 RPM Steps. 3 stages of Ignition Retard - Each one Adjustable 1 to 25 degrees in tenth degree steps. Adjustable Automatic Start Retard. Selectable High Speed Advance Slope. Features At A Glance: No Chips required For Adjustments. Easy to use push button controls. Upgrade your Hyfire 7S to a 7C, 7CR, 7C BTR without changing your Entire Ignition. Upgrade your present Hyfire 7C to a 7CR, 7C BTR without changing your Entire Ignition. RPM Switch (When Upgrading a HyFIRE 7C Only). Simply plug in the new controller and wire up the new features.
Part Number:
674M
|
|
HYFIRE 7CR CONTROLLER
HyFIRE 7CR Controller: 2 Stages of Rev Limiting in 50 RPM Steps. 4 stages of Ignition Retard- Each one Adjustable .1 to 25 degrees in tenth degree steps. Adjustable Automatic Start Retard. Selectable High Speed Advance Slope. Features At A Glance: No Chips required For Adjustments. Easy to use push button controls. Upgrade your Hyfire 7S to a 7C, 7CR, 7C BTR without changing your Entire Ignition. Upgrade your present Hyfire 7C to a 7CR, 7C BTR without changing your Entire Ignition. RPM Switch (When Upgrading a HyFIRE 7C Only). Simply plug in the new controller and wire up the new features.
Part Number:
678
|
|
HYFIRE VIIC BTR PRO-RACING IGNITION
HyFIRE VIIC BTR Professional Racing Ignition Features at a Glance: 3 Stages of Rev Limiting in 50 RPM Steps. 3 stages of Ignition Retard - Each one adjustable .1 to 25 degrees in tenth degree steps. Adjustable Automatic Start Retard. Selectable High Speed Advance Slope Boost Proportional Retard Harness with 3 BAR MAP Sensor included. Primary Output Voltage: 550, Secondary Voltage Output: 50000, Spark Energy: 160mj. Must use Mallory coil #28880.
Part Number:
667BTR
|
|
HYFIRE VIIC PROFESSIONAL RACING IGNITION
HYFIRE VIIC Professional Racing CD Ignition Features At A Glance: Three rev limiters - adjustable from 1,000 to 12,000 RPM in 100 RPM increments. Three retard stages - adjustable from .1 to 25 degrees. RPM activated switch. High speed advance - adjustable cut-in from 5,000 to 12,000 and a slope of .1 to 3 degrees per 1,000 RPM. Automatic start retard. Easy reading remote digital display with simple push button adjustability. Easy to upgrade for additional features. Primary Output Voltage: 550, Secondary Voltage Output: 50000, Spark Energy: 160mj. Must use Mallory Coil #28880.
Part Number:
667C
|
|
HYFIRE VIICR PROFESSIONAL RACING IGN.
HYFIRE VIICR Professional Racing Ignition Features At A Glance: Two rev limiters - adjustable from 1,000 to 12,000 RPM in 100 RPM increments. Four retard stages - adjustable from .1 to 25 degrees. RPM activated switch. High speed advance - adjustable cut-in from 5,000 to 12,000 and a slope of .1 to 3 degrees per 1,000 RPM. Automatic start retard. Easy reading remote digital display with simple push button adjustability. Easy to upgrade for additional features. Must use Mallory Coil #28880. Primary Output Voltage: 550, Secondary Voltage Output: 50000, Spark Energy: 160mj.
Part Number:
667CR
|
|
HYFIRE VIIS SPORTSMAN RACING IGNITION
HYFIRE VIIS Sportsman Racing CD Ignition Features At A Glance: Two rev limiters - adjustable from 1,000 to 12,000 RPM in 100 RPM increments. Single stage retard - adjustable from .1 to 25 degrees. Automatic start retard. 550 volts to coil primary, 150 mJ per spark. Easy reading top mounted digital display. Simple push-button adjustability. Easy to upgrade for more features. Easy to upgrade to 667C with purchase of #674M controller. Must use Mallory Coil #28880.
Part Number:
667S
|